Friday 16 July 2021

Aerocon panels Specifications


Technical Specifications

Properties                                     Thickness                                     Remarks

                                                  50mm &75mm

  Weight per SQM                     39             54                                  Nominal Weight

  Axial Load/meter width                                                                 Factor of safety-2.5

  (kn/m)                                     53             83                                   Sample size(1500x300mm)

  Bending Test(4 point UDL)

  (kg/m2)

  (2.9m span)                            66             95                                    Factor of safety-2.5 

  (1.5m span)                            198           295

 Flexural Strength/                   67             58                                    Typical test results

Modulus of Rupture

(Kg/cm2)

Thermal Conductivity             0.22          0.21                                 BS 4370 - Part 2

(W/m deg.k)

Sound Transmission                33            36                                     IS:9901 (part III) -1981

Coefficient(db)                                                                                 IS:11050(part I)   -1981

Fire Rating(minutes)              60             120                                   BS476 Part 20 - 22






Monday 12 July 2021

Fire Separation wall



 

 Due To Good Fire rating properties, Aerocon panels Are more suitable For fire separation walls where 

Fire Rating of two hours is generally expected. Aerocon panels come with a test backup from the 